{"id":722,"date":"2026-11-10T03:52:04","date_gmt":"2026-11-09T19:52:04","guid":{"rendered":"http:\/\/www.interseamarine.com\/blog\/?p=722"},"modified":"2026-11-10T03:52:04","modified_gmt":"2026-11-09T19:52:04","slug":"what-is-the-starting-torque-of-an-ac-servo-motor-4e4b-4a84f5","status":"publish","type":"post","link":"http:\/\/www.interseamarine.com\/blog\/2026\/11\/10\/what-is-the-starting-torque-of-an-ac-servo-motor-4e4b-4a84f5\/","title":{"rendered":"What is the starting torque of an AC servo motor?"},"content":{"rendered":"<p>What\u2019s the Starting Torque of an AC Servo Motor, Anyway? \u2013 A Supplier\u2019s No-BS Breakdown <a href=\"https:\/\/www.auricmotor.com\/servo-motor\/ac-servo-motor\/\">AC Servo Motor<\/a><\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.auricmotor.com\/uploads\/43962\/small\/36v-brushless-motor-59029983.jpg\"><\/p>\n<p>If you\u2019ve ever shopped for AC servo motors for industrial machines, robotics, or even medical devices, you\u2019ve probably seen \u201cstarting torque\u201d thrown around in spec sheets. It\u2019s one of those terms that sounds super technical, like something only engineers with slide rules would argue about \u2013 but once you dig into it, it\u2019s actually one of the most important specs you\u2019ll ever look at for your application. I\u2019ve been supplying AC servo motors for over 10 years now, and I can\u2019t tell you how many times a customer will come to me saying, \u201cMy motor won\u2019t turn on startup\u201d or \u201cIt stalls every time I load a part\u201d \u2013 and nine times out of 10, the issue isn\u2019t the motor size, it\u2019s the starting torque. Let\u2019s break this down like we\u2019re chatting over a coffee, no jargon overload, and explain exactly what starting torque is, why it matters, and how to get the right one for your project.<\/p>\n<p>First, let\u2019s get the super basic definition out of the way, in plain English. Torque is just rotational force, right? Like when you twist a doorknob, that\u2019s torque. Starting torque (sometimes called stall torque, which is the exact peak torque a motor can deliver when it\u2019s not turning at all \u2013 that\u2019s the starting part) is the maximum amount of twist an AC servo motor can generate the second it powers on, before it starts spinning. A lot of people mix this up with rated torque, which is the steady, constant torque a motor can keep putting out for long periods of time without overheating. Those are two totally different numbers, and using them interchangeably is how you end up with a motor that works fine when it\u2019s already spinning, but dies the second you try to get it moving.<\/p>\n<p>Wait, let\u2019s clarify that with a real example from my business. Last year, a customer who builds packaging lines reached out panicking. They had a small conveyor belt that needed to lift 5kg boxes onto a pallet, and they\u2019d bought a standard induction motor (not a servo, but they didn\u2019t know the difference) rated for 10N\u00b7m of torque. But every time they turned the belt on, the motor would hum loudly and not move \u2013 it was overloading and tripping the circuit breaker. They called me thinking they needed a bigger motor, but when I checked their specs, their startup torque requirement was actually around 8N\u00b7m, while that induction motor only had a starting torque of 3N\u00b7m. The induction motor\u2019s rated torque was high, but its starting torque was garbage because it\u2019s designed for constant, steady-speed operation, not precision startup with a load. That\u2019s where AC servo motors shine \u2013 their starting torque is almost always equal to or higher than their rated torque, because they\u2019re built to handle sudden loads, which is exactly what most automated applications deal with.<\/p>\n<p>Now, how do AC servo motors actually produce that starting torque? Let\u2019s keep this simple, no deep physics unless you want it. Unlike old DC motors that used brushes to create magnetic fields, AC servo motors use permanent magnets and variable-frequency drives (VFDs, sometimes called amplifiers) to control the current to the stator windings. When you power on an AC servo, the VFD sends a precise burst of current to create a rotating magnetic field that interacts with the permanent magnets on the motor\u2019s rotor. The second that field locks onto the rotor, that\u2019s the starting torque \u2013 it\u2019s instantaneous, because there\u2019s no lag from brushes or a need to build up speed to generate force. Induction motors, by contrast, need to build up current in the rotor to create torque, which takes time \u2013 that\u2019s why their starting torque is lower. That lag is fine for a fan, but terrible for a robotic arm that needs to pick up a part and move it 10cm in 0.5 seconds.<\/p>\n<p>Here\u2019s another key point: AC servo motors can hold that starting torque indefinitely, as long as you don\u2019t exceed their temperature limits. If you ever see a spec sheet that says \u201cstall torque\u201d with a note like \u201cnot continuous,\u201d that\u2019s not a true servo motor \u2013 that\u2019s probably a stepped or open-loop motor, which we don\u2019t carry at our company. All our AC servo motors have rated starting torque that\u2019s designed for both startup and momentary loads, which is critical for things like machine tools that cut metal, where you need to apply full force the second the tool touches the workpiece.<\/p>\n<p>Now, why is starting torque such a big deal for your application, specifically? Let\u2019s run through the most common scenarios our customers ask about:<\/p>\n<p>Robotics: If you\u2019re building a robotic arm that lifts a 2kg gripper with a 1kg part on it, the startup torque has to account for the full weight of the arm, the inertia of the moving parts, and any friction in the joints. If your starting torque is too low, the arm will jerk, stall, or even drop the part \u2013 which is a safety hazard for medical robots or factory automation lines. Last quarter, we sold a set of 200W AC servo motors to a medical device manufacturer that builds small surgical robots; they needed precise, consistent starting torque to move tiny instruments without vibrating, and our motors checked out at 0.6N\u00b7m starting torque, which was exactly what their design required.<\/p>\n<p>Packaging &amp; Conveying: Like that earlier customer, packaging lines have to stop and start constantly, picking up heavy boxes or crates on startup. If your motor can\u2019t generate enough starting torque, you get bottlenecks, downtime, and damaged products. Our standard 400W AC servo motors have a starting torque of 1.27N\u00b7m, which works for most mid-sized conveyor lines, but we also have higher-torque models for heavy-duty palletizing lines that need 5N\u00b7m+ of starting torque.<\/p>\n<p>CNC Machining: When a CNC tool touches a piece of metal, that\u2019s a sudden, huge load \u2013 the motor has to apply full torque instantly to keep the tool from stalling or skipping. AC servo motors\u2019 high starting torque is exactly why they\u2019re the go-to for CNC machines, way better than old DC motors or even induction motors. I once had a CNC shop owner tell me he switched from induction motors to our AC servos and cut his stalling incidents by 90% \u2013 that\u2019s the difference between good starting torque and bad.<\/p>\n<p>Wait, but here\u2019s a myth I hear all the time: \u201cHigher starting torque is always better.\u201d No, that\u2019s not true. If you oversize your motor for starting torque, you\u2019re wasting money on energy and space, which adds up over time. For example, a customer building a small pick-and-place robot came to me wanting a 1kW motor because he thought higher torque = better, but his actual startup requirement was only 0.3N\u00b7m. A 200W motor with 0.5N\u00b7m starting torque would have done the job perfectly, and he would have saved $1,200 on initial cost plus $300 a year in electricity. The key is to calculate your exact required starting torque, not just grab a big number.<\/p>\n<p>How do you calculate the starting torque you need? I don\u2019t expect you to pull out a textbook, and most suppliers will help you with this, but let\u2019s give you the quick, dirty way. The formula boils down to torque needed to overcome friction plus torque needed to accelerate your load. For rotational loads (like a motor shaft turning a gear), that\u2019s: Starting Torque = (J * \u03b1) + T_friction, where J is the inertia of your load, \u03b1 is your desired angular acceleration (how fast you want the motor to spin up), and T_friction is the torque lost to bearings, gears, etc. If you\u2019re dealing with linear loads (like a conveyor belt moving a box), you can convert linear force to torque: Torque = (Force * Radius) \/ Efficiency of your gear system.<\/p>\n<p>Most good AC servo motor suppliers (read: us) will walk you through this calculation for free, no sales pitch attached. We\u2019ve got a team of application engineers who spend all day helping customers match the right motor to their exact startup needs, so you don\u2019t have to guess. I\u2019ve seen way too many customers buy motors online just based on power ratings, and then end up with something that doesn\u2019t work \u2013 that\u2019s why we prioritize starting torque specs on our product pages, not just raw wattage.<\/p>\n<p>Another thing that affects starting torque: the VFD (or servo drive) you pair with your motor. A cheap, off-the-shelf VFD might not send enough current to the motor\u2019s stator when it starts up, so even if your motor has a spec of 2N\u00b7m starting torque, you might only get 1N\u00b7m in practice. That\u2019s why we only sell matched sets of AC servo motors and drives \u2013 they\u2019re calibrated to work together, so you get exactly the starting torque listed in the spec sheet, no surprises. I can\u2019t tell you how many times a customer bought a cheap motor from a random seller and a cheap VFD off Amazon, and came to us saying \u201cyour motor\u2019s torque is higher, why isn\u2019t it working?\u201d 9 times out of 10, the drive was underpowered or not calibrated for the motor.<\/p>\n<p>What about common mistakes people make when choosing starting torque? Let\u2019s list the top three, since I see them every week:<\/p>\n<ol>\n<li>\n<p>Mixing up starting torque and rated torque: Like that packaging line customer, someone will look at the rated torque of a motor (which is what it does when it\u2019s already spinning steady) and assume that\u2019s the startup torque. Big mistake \u2013 AC servos are the only motors where these numbers are almost the same, but even then, always check the \u201cstall torque\u201d number, which is the starting torque. Induction motors have starting torque that\u2019s 50-70% of their rated torque, so if a motor has 10N\u00b7m rated, it only has 5-7N\u00b7m starting \u2013 that\u2019s why it stalls on startup.<\/p>\n<\/li>\n<li>\n<p>Forgetting inertia: Your load\u2019s inertia is way more important than its weight when it comes to starting torque. If you have a heavy part that\u2019s spinning on a shaft, the inertia is based on how fast you want to spin it, not just how much it weighs. For example, a 5kg plate spinning at 1000 RPM has way more inertia than a 10kg plate spinning at 100 RPM, so you need more starting torque for the faster spin. That\u2019s why we always ask customers about their desired speed and acceleration, not just the weight of their load.<\/p>\n<\/li>\n<li>\n<p>Ignoring environmental factors: If your motor is going to be in a cold warehouse, high-temperature factory, or dusty outdoor environment, that affects starting torque. Cold makes motor magnets stronger, so torque goes up a little, but heat can make magnets weaker, so torque can drop by 10-15% if it\u2019s too hot. That means if your application is in a 50\u00b0C factory, you need to oversize your starting torque by 10% to compensate for that drop. We have motors rated for extreme temps and dusty environments, so just tell our team where your motor will be used, and we\u2019ll adjust the spec accordingly.<\/p>\n<\/li>\n<\/ol>\n<p>Let\u2019s circle back to my role as an AC servo motor supplier, because that\u2019s who I am \u2013 not a textbook author, not a random engineer, but someone who\u2019s dealt with thousands of customers and their motor headaches. We don\u2019t just sell motors; we solve problems. When a customer calls us saying \u201cmy motor stalls on startup,\u201d we don\u2019t just point to the spec sheet and say \u201cthat\u2019s not our problem.\u201d We ask them to tell us about their application: what are they moving, how fast, what\u2019s the load, what\u2019s the environment, and then we walk them through whether their starting torque is too low, their drive is wrong, or they just need a motor sized for their needs.<\/p>\n<p>Last month, we had a small business owner who builds custom display stands for trade shows. He was using a stepper motor that would jitter on startup, and his stands would tip over when he loaded a screen. We recommended a 100W AC servo motor with 0.32N\u00b7m starting torque, paired with a matched drive. He installed it, and now his stands start smoothly, no jitter, and he can load the full screen without any issues. He sent me a video of it at a trade show, and it\u2019s one of my favorite stories \u2013 because it\u2019s a small customer, not a big corporation, that just needed the right starting torque.<\/p>\n<p>If you\u2019re in the market for an AC servo motor, whether it\u2019s for robotics, packaging, CNC, medical devices, or any other application where startup performance matters, don\u2019t get stuck on power ratings or brand names. Ask about the starting torque (stall torque) spec, calculate your exact required torque, and make sure you\u2019re pairing the motor with a matched drive if you want consistent performance. If you\u2019re not sure where to start, or you need help calculating your required starting torque, our team is here to help. We don\u2019t do hard sells, we don\u2019t have fancy marketing that hides the specs, and we\u2019ve been around long enough to know that the best motor is the one that works for your specific application, not the most expensive or the biggest.<\/p>\n<p><img decoding=\"async\" src=\"https:\/\/www.auricmotor.com\/uploads\/43962\/small\/bevel-geared-motor075da.jpg\"><\/p>\n<p>So to wrap this up: Starting torque is the maximum rotational force an AC servo motor generates the second it powers on, before it starts spinning. It\u2019s critical for applications where you need to get a load moving quickly and reliably, unlike induction motors which have lower starting torque and lag. Always distinguish starting torque from rated torque, calculate your exact requirements, account for inertia and environmental factors, and make sure you pair your motor with a matched servo drive. If you have questions about choosing the right AC servo motor for your project, we\u2019re here to help you find the perfect fit for your needs.<\/p>\n<p><a href=\"https:\/\/www.auricmotor.com\/servo-motor\/switched-reluctance-motor-4400\/\">Switched Reluctance Motor<\/a> References<\/p>\n<ol>\n<li>AC Servo Motor Fundamentals, Motion Control Association, 2021<\/li>\n<li>Torque Basics for Industrial Automation, IEEE Industry Applications Magazine, 2019<\/li>\n<li>Servo Motor Selection Guide: Starting Torque Calculations, Automation Direct Technical Documentation, 2022<\/li>\n<\/ol>\n<hr>\n<p><a href=\"https:\/\/www.auricmotor.com\/\">Zibo Auric Mechanical and Electrical Technology Co., Ltd.<\/a><br \/>As one of the leading ac servo motor manufacturers and suppliers in China, we warmly welcome you to buy advanced ac servo motor for sale here from our factory. All customized motors are with high quality and competitive price.<br \/>Address: B419, High-tech Entrepreneurship Park, High-tech Zone, Zibo City<br \/>E-mail: cui@auricmotor.com<br \/>WebSite: <a href=\"https:\/\/www.auricmotor.com\/\">https:\/\/www.auricmotor.com\/<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>What\u2019s the Starting Torque of an AC Servo Motor, Anyway? \u2013 A Supplier\u2019s No-BS Breakdown AC &hellip; <a title=\"What is the starting torque of an AC servo motor?\" class=\"hm-read-more\" href=\"http:\/\/www.interseamarine.com\/blog\/2026\/11\/10\/what-is-the-starting-torque-of-an-ac-servo-motor-4e4b-4a84f5\/\"><span class=\"screen-reader-text\">What is the starting torque of an AC servo motor?<\/span>Read more<\/a><\/p>\n","protected":false},"author":401,"featured_media":722,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[685],"class_list":["post-722","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry","tag-ac-servo-motor-4911-4b3577"],"_links":{"self":[{"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/posts\/722","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/users\/401"}],"replies":[{"embeddable":true,"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/comments?post=722"}],"version-history":[{"count":0,"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/posts\/722\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/posts\/722"}],"wp:attachment":[{"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/media?parent=722"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/categories?post=722"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/www.interseamarine.com\/blog\/wp-json\/wp\/v2\/tags?post=722"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}