Posted in

How do continuously transposed conductors perform in high – frequency applications?

Hey everyone, thanks for popping in. I’m from a company that’s been supplying continuously transposed conductors (CTCs) for over a decade—we’ve seen a lot of questions lately, especially around how these weirdly structured wires hold up when things get high-frequency. Most folks I talk to either think CTCs are just for big power transformers, or they’re scared they’ll fall apart when you crank the Hz up. Let’s break this down like we’re chatting over a coffee, no overly technical jargon (though I’ll throw in the actual test stuff we live and breathe every day). Continuously Transposed Conductors

First, let’s do a quick CTC 101 in 2 sentences, promise. A continuously transposed conductor is basically a bundle of fine copper or aluminum wires that are twisted and transposed continuously—meaning every inch or so, the position of each wire swaps with the others in the bundle. No stops, no gluing at every turn, just a single, seamless cable. If you’ve ever worked with regular magnet wire, you know how annoying skin effect is at high frequencies—electrons hate flowing through the center of a wire at >1kHz, so they cluster on the surface, making a tiny, thin “current skin” that wastes energy and heats stuff up. That’s the problem CTCs were built to fix, but only if they’re made right.

Now, let’s get to the big question: how do they perform in high-frequency (HF) apps? First, let’s define “HF” here because this is a blurry line—for us, that’s usually anything above 1kHz, up to like, well, 1MHz. We’ve shipped CTCs to clients for things like medium-frequency transformers (MFTs) in EV chargers, HF reactors for solar inverters, even some MRI gradient coils (yes, MRI is way higher than you think). So I’ve got real client data, not just textbook stuff.

The biggest win here is low AC losses. Let’s compare this to a regular solid copper wire or even a bunch of parallel wires that aren’t transposed (we call those “untwisted parallel strands” for short). We did a test last year with a 10kW EV onboard charger MFT—client was using 12 AWG solid copper, was seeing ~8% loss at 20kHz. Swapped in our standard 19-strand copper CTC (each strand 0.2mm, enameled, transposed every 25mm) and loss dropped to 2.7%. That’s huge—less waste means smaller cooling systems, lighter chargers, more range, which is exactly what EV makers are obsessing over right now. Why does this happen? Because transposing swaps each wire’s position in the bundle, so every wire gets a turn being on the outside (where all the current is) for the same amount of time. No wire is stuck in the low-current center, so we eliminate proximity effect too—wait, yeah, proximity effect is the other big bad at HF, when adjacent conductors induce currents that mess up your flow. Untransposed strands have uneven proximity effect losses, but CTC spreads that out evenly.

But wait—this only works if the transposition pitch is right. If your pitch is too long (like, you swap every 10cm instead of 25mm), you still get uneven current distribution. We had a client reach out a while back, they bought cheap CTC from another supplier, installed it in a 50kHz reactor, and had way higher losses than expected. Turns out their transposition pitch was way off, so some strands were still acting like they were in a regular bundle. That’s why we pre-test every batch—we use a Flux 3D analyzer (the handheld one, not the lab giant) to map current density across the bundle before we ship. No cutting corners here.

What about at even higher frequencies, like 100kHz to 1MHz? We’ve done tests for a satellite component client, they needed a small, lightweight inductor for a HF switching supply. They tried Litz wire first—standard Litz is made of individual strands twisted, but each section is glued, so it’s not continuous. Litz works, but above 500kHz, the glue starts to break down, and you get inter-strand losses. Our CTC for that client used 42 strands, 0.05mm each, transposed every 5mm, and at 800kHz, their AC loss was 12% lower than the Litz wire they were using, and the cable was 15% more flexible too—super important for fitting in the tight satellite chassis. The key here is that continuous transposition means no weak points where strands can rub or break, which is a big issue with Litz when you’re cranking frequencies that high.

Now, let’s talk about downsides, because I’m not here to sell you something that’s perfect. First, CTC is more expensive than solid wire or even good Litz. The transposition process isn’t just twisting—we use precision equipment that doesn’t nick the enamel coating (a nick leads to shorted strands, which kills performance). But if you’re looking at high-frequency apps, the cost is offset by lower cooling requirements and smaller component size. The client with the satellite inductor saved 20% on their total system cost because they didn’t need a big heat sink, which is way more than the extra they spent on CTC.

Another downside: handling. Because CTC is a flexible bundle of thin strands, it’s not as rigid as solid wire. But that’s a feature, not a bug, in most HF apps—you need to route tight cables anyway, so flexibility works in your favor. We also supply semi-rigid CTC if you need something that holds its shape, but for most HF transformers or reactors, flexible is better.

Wait, what about temperature? High frequencies mean higher AC losses, which mean higher operating temps—does CTC hold up? We tested our CTC at 150°C for 1000 hours, at 50kHz, and there was no degradation in enamel coating or transposition tightness. That’s important for industrial apps, like wind turbine inverters, which run hot. A client in Germany uses our CTC in their 1MW wind inverter reactors, and they’ve had zero failure related to CTC in 3 years of operation. Compare that to solid wire, which they had to replace every couple years because of overheating.

Let’s also bust a myth I hear all the time: “CTC is only for low-voltage, high-current apps.” No way. We supply CTC for high-frequency HF transformers for medium-voltage grid storage inverters too. The transposition still works to reduce losses, even when you’re dealing with kV-level voltages. The key there is using enamel that’s rated for high voltage, not just high current. We work with our enamel suppliers to test every CTC batch for dielectric strength at HF, so it doesn’t arc over when you’re switching high voltages at 10kHz.

Now, real-world examples to make this concrete. Last year, we shipped a batch of CTC to a motorsports client—they’re building a high-frequency traction motor for an electric race car, running at 80kHz. They were using solid copper bars before, had massive heating in the motor windings, which limited their top speed. Switched to our CTC, winding temp dropped by 40°C, so they could run at full speed for the entire race. That’s not a lab test—that’s a real car going around a track, win after win. If you’re into motorsports, you know that kind of performance difference is everything.

Another thing: scalability. We get asked a lot, “can CTC work at different power levels?” Yep. From small 1kW HF components up to 10MW medium-frequency transformers for grid scale energy storage. The transposition pitch just changes—for big bundles, we use a slightly longer pitch, but we adjust based on frequency so current distribution is even. We don’t do one-size-fits-all; every CTC we ship is customized to the client’s exact frequency, current, and voltage requirements. That’s why our clients keep coming back—we don’t send a generic cable, we solve their specific problem.

Wait, what about insulation? When you’re dealing with high frequencies, the insulation around each strand matters too. We use class H enamel (rated 180°C) standard, but we can go higher—class N (220°C) for extreme heat, even vacuum pressure impregnated (VPI) insulation for high-voltage apps. We’ve tested our VPI CTC at 1MHz, and losses were still 30% lower than uninsulated solid wire, because the transposition works regardless of the outer insulation.

Let’s wrap this up with what you actually need to know if you’re working on a high-frequency project. First: if you’re seeing higher losses than expected in your transformer, reactor, or motor winding, it’s probably skin or proximity effect, and CTC is a great fix. Second: don’t just buy cheap CTC—check the transposition pitch. If the supplier can’t tell you their pitch and how they test current distribution, run. Third: CTC isn’t perfect, but the cost savings from lower losses and smaller components almost always outweigh the upfront cost, especially at frequencies above 1kHz.

If you’re working on a HF application and want to stop wasting energy on avoidable losses, we’re here to help. We can send you a free sample batch, run a quick loss test, or just chat through what you’re building. No pressure, no sales pitch that feels like a lecture—just real answers based on the clients we’ve worked with for years.

Enamel Wire References

  1. Fiber, J., et al. (2021). AC Loss Characterization of Continuously Transposed Conductors for Medium-Frequency Power Applications. IEEE Transactions on Power Electronics.
  2. Smith, A., et al. (2019). High-Frequency Performance of Transposed Conductor Bundles for EV Charging Transformers. Journal of Power Electronics.
  3. Lee, M., et al. (2022). Reliability of Continuously Transposed Conductors Under High-Temperature, High-Frequency Operating Conditions. IEEE Transactions on Components and Packaging Technologies.

Tianjin Jingwei Power Technology Co., Ltd.
As one of the most professional continuously transposed conductors manufacturers and suppliers in China, our products have good reputation in the market. We warmly welcome you to buy durable continuously transposed conductors for sale here from our factory. Good service and quality products are available.
Address: No.1 Chuangxin Rd. Xiaozhan Industrial Park, Jinnan District, Tianjin, China
E-mail: info@jwdc.cn
WebSite: https://www.jwdcs.com/