If you’ve ever stood in a power distribution room watching a low voltage switchgear unit hum steadily in the background, you might not have noticed the thick, solid bars running through its interior—often called busbars. As someone who’s been a low voltage switchgear supplier for over a decade, I can tell you that these busbars are far more than just structural pieces; they’re the lifelines that carry consistent, safe electrical current to everything from office building lighting to industrial assembly lines. One of the most common questions I get from engineers, electricians, and project managers isn’t just “what are busbars?” but “what cross-sections of busbars do we actually use for low voltage applications?” Low Voltage Switchgear

First, let’s ground this in context. Low voltage switchgear typically handles currents up to around 5,000 amps, and at that level, even a small mistake in busbar cross-section can lead to overheating, voltage drops, or even catastrophic failure. Busbar cross-section refers to the total area of the conductive bar that carries current, usually measured in square millimeters (mm²) or sometimes square inches for projects in regions that use imperial units. The cross-section directly correlates to how much current the busbar can safely carry, how much heat it will generate, and how well it fits within the compact footprint of modern low voltage switchgear.
When I first started out in this business, I thought bigger was always better. I’d get calls from new contractors who’d spec a 100mm² busbar for a 200-amp circuit, just to err on the side of caution. But over time, I learned that it’s all about matching the cross-section to the specific load, environment, and switchgear design. There’s no one-size-fits-all, but there are standard cross-sections that we consistently rely on for low voltage switchgear, and knowing these is the difference between a switchgear unit that works for 20 years and one that needs replacing in five.
Let’s start with the smallest cross-sections, which we use for light-duty low voltage applications. For circuits carrying up to 100 amps, we commonly use 10mm², 16mm², and 25mm² busbars. These are usually thin, flat copper bars—sometimes aluminum for lighter loads, though copper is still the go-to for its higher conductivity. I remember a small office project a few years back where the electrician tried to use aluminum busbars for the 80-amp lighting circuits. It worked temporarily, but after a year, the connections started corroding because aluminum oxidizes faster than copper, especially in the slightly humid basement power room. We ended up swapping them out for 16mm² copper busbars, and that unit has run without issues since. For these light loads, the cross-section needs to be just large enough to handle the current without excessive resistance, which generates heat. If a 16mm² bar is used for a 50-amp circuit, it’s fine, but if you push it to 100 amps, it will overheat during peak load times, especially if the switchgear isn’t properly ventilated.
Moving up to medium-duty applications, which are the most common in commercial and small industrial settings. For currents between 100 amps and 1,000 amps, the standard cross-sections jump to 35mm², 50mm², 70mm², 95mm², and 120mm². These are thicker bars, often shaped as flat rectangles to maximize surface area for heat dissipation—heat is the biggest enemy of busbars, so maximizing surface area without making the switchgear too bulky is key. A lot of our mid-sized retail chain projects use 70mm² busbars for their main feeders, which carry 400 amps to power the store’s lighting, HVAC, and cash registers. We also use these cross-sections for branch circuits in switchgear that serves multiple small tenants in a commercial building. What’s important here is that we don’t just pick a cross-section based on current rating; we also factor in the ambient temperature of the switchgear room. If a room is consistently warm, say 35°C instead of the standard 30°C used in most ratings, we bump up the cross-section by about 10% to prevent overheating. A customer once tried to cut costs by using a smaller cross-section in a poorly ventilated utility closet, and within six months, the busbar insulation started melting because the bar was running too hot. That’s a mistake I still warn new customers about.
For heavy-duty low voltage applications, which include large industrial facilities, data centers, and high-rise buildings, we use cross-sections from 150mm² up to 500mm², and sometimes even larger for currents approaching 5,000 amps. These are heavy-duty copper bars, often with multiple parallel bars for very high currents—you’ll see two or three 200mm² bars running side by side for a 3,000-amp feeder, for example. The cross-section here is critical because these circuits power the backbone of a building or plant. I worked on a data center project a few years ago where the design team initially spec’d 300mm² busbars for the main distribution switchgear. But after doing a heat load calculation, we realized that a 320mm² cross-section would reduce operating temperature by nearly 10°C, which would translate to lower energy costs over the life of the unit. The client was hesitant at first, but when we showed them the ROI on the extra material cost—around 5% upfront, vs. 15% lower annual energy bills—they agreed, and that switchgear unit has been running efficiently for four years now. For these high-current applications, we also have to consider the busbar’s length and the voltage drop. A longer busbar needs a slightly larger cross-section to keep voltage drop within acceptable limits, usually less than 2% for low voltage systems.
Now, it’s not just about the cross-section size—shape also plays a role, and that ties back to cross-section performance. Most low voltage busbars use flat rectangular cross-sections, but sometimes we use circular or tubular bars for very high currents, though that’s less common. Flat bars have a higher surface area-to-cross-section ratio than round bars, which helps dissipate heat faster, making them more efficient for switchgear. There’s also something called skin effect, which causes current to flow closer to the surface of the busbar as frequency increases. For low voltage systems (which operate at 50Hz or 60Hz), skin effect is minimal, so it doesn’t drastically change the required cross-section, but it’s still something we factor in when designing for very high currents.
Another thing I want to mention is material choice paired with cross-section. While copper is the most conductive, aluminum is lighter and cheaper, so we use it for some low to medium current applications where weight is a concern, like in portable switchgear or outdoor units. But aluminum has about 60% the conductivity of copper, so you need a larger cross-section to carry the same current. For example, a 70mm² aluminum busbar carries roughly the same current as a 50mm² copper bar, so we always specify material along with cross-section to our customers. I’ve seen projects where someone tried to use aluminum busbars with the same cross-section as copper, leading to overheating and power outages. It’s a common mistake, and one that’s easily avoided by checking conductivity ratings.
As a supplier, I also work closely with our engineering team to test busbar cross-sections under real-world conditions. We run temperature tests at full load, short-circuit tests, and vibration tests (for switchgear in industrial settings with heavy machinery) to make sure our cross-section specs are accurate. A few years ago, we noticed that a 120mm² busbar we were using for 800-amp circuits was running a bit hot in switchgear that had a tight, enclosed design. Instead of switching to a larger cross-section, we adjusted the bar’s aspect ratio—making it wider and thinner, which increased surface area without adding too much bulk. That small change solved the heat issue, and we still use that design today for enclosed switchgear units.
When it comes to standards, we always follow IEC 60439 for low voltage switchgear and controlgear, which specifies the minimum required cross-sections based on current ratings and operating conditions. There are also regional standards, like NEC in the US, which has specific ampacity tables for busbars. As a supplier, we don’t cut corners on following these standards, because a busbar that doesn’t meet IEC or NEC specs isn’t just a safety hazard—it’s illegal in most regions.
Now, you might be wondering how to choose the right cross-section for your project. Start by getting the exact current rating of each circuit, the ambient temperature of the switchgear room, the length of the busbar run, and whether you’re using copper or aluminum. If you’re working with an engineer, they’ll do the calculations, but if you’re a project manager or electrician, don’t hesitate to reach out to us as a supplier. We’ve seen hundreds of projects, and we can help you avoid costly mistakes like undersized cross-sections for high heat environments or using aluminum where copper is necessary.
I think it’s also important to talk about maintenance, because the cross-section of your busbars affects how long they’ll last. A properly sized busbar with the right material will have lower resistance, so it won’t heat up as much, which reduces wear on the insulation and connections. We recommend annual inspections of busbar connections, especially for cross-sections over 100mm², to check for corrosion or loose bolts—loose connections increase resistance, which leads to overheating, even if the cross-section is correct.
Over the years, I’ve learned that the best low voltage switchgear isn’t just about the brand of the circuit breakers or the size of the enclosure—it’s about the details, like the right busbar cross-section. Too many people overlook these bars, but they’re the ones that keep the power flowing day in and day out. I’ve had customers come back to us after 15 years, saying their switchgear is still running perfectly, and when we look at the specs, the busbar cross-section was spot-on for the load and environment. That’s the kind of work that builds trust, and it’s why I’ve stayed in this business for so long.

If you’re working on a project and need help determining the right busbar cross-sections for your low voltage switchgear, don’t hesitate to reach out for a consultation. We can provide custom designs based on your specific load requirements, environment, and budget, and we’ll make sure every detail meets safety and performance standards.
Transformer References
IEC 60439-1: Low-voltage switchgear and controlgear assemblies – Part 1: General rules
National Electrical Code (NEC) Article 376: Busways and Busbars for Low Voltage Applications
ANSI/IEEE Standard 141: Recommended Practice for Electric Power Distribution for Industrial Plants (Red Book)
Deepwill International Technology Development (Jiangsu) Co., Ltd.
Deepwill International Technology Development (Jiangsu) Co., Ltd. is one of the most professional low voltage switchgear manufacturers and suppliers in China, featured by quality products and good price. Please rest assured to buy low voltage switchgear for sale here from our factory. Contact us for OEM service.
Address: No. 3-3 muyang Road, Hanjiang Economic Development Zone, Yangzhou city, Jiangsu Province, China.
E-mail: deepwill@deep-will.com
WebSite: https://www.deyunelectric.com/